4.14 Changer un disque et le faire clignoter

De UnixWiki
Aller à la navigation Aller à la recherche

Si un disque est HS on voit dans l'errpt:

 # errpt
 IDENTIFIER TIMESTAMP  T C RESOURCE_NAME  DESCRIPTION
 425BDD47   0425035512 P H hdisk3         DISK OPERATION ERROR
 16F35C72   0425035512 P H hdisk7         DISK OPERATION ERROR
 425BDD47   0425032412 P H hdisk3         DISK OPERATION ERROR

Pour voir sa configuration:

 # lscfg -vpl hdisk3
 hdisk3           U0.1-P2-I6/Z2-A8  16 Bit LVD SCSI Disk Drive (36400 MB)
Manufacturer................IBM Machine Type and Model......ST336753LC FRU Number..................55P4098 ROS Level and ID............43353141 Serial Number...............0010C03F EC Level....................H31325 Part Number.................55P4096 Device Specific.(Z0)........000003129F00013E Device Specific.(Z1)........0626C51A Device Specific.(Z2)........0002 Device Specific.(Z3)........04174 Device Specific.(Z4)........0001 Device Specific.(Z5)........22 Device Specific.(Z6)........H31325

PLATFORM SPECIFIC
Name: sd Node: sd Device Type: block

Il faut donner le FRU Number à IBM pour qu'ils identifie le type de disque.

Pour faire clignoter un disque (afin que le technicien le trouve si il est dans une petite baie):

 # diag  -d $hdisk -T "identifyRemove -a identify

Une fois que le technicien l'a changé, on découvre le nouveau disques avec un

 # cfgmgr